Endovascular stenting of a leaking thoracic aortic pseudoaneurysm
Document Type
Report
Department
Cardiothoracic Surgery
Abstract
Rupture of an aortic aneurysm is a major cause of early mortality during the course of disease. A less invasive approach with fewer complications is sought. A case of leaking thoracic aortic aneurysm is presented, where endovascular approach was adapted owing to ongoing sepsis. This report indicates prospects for employment of endovascular stenting as a suitable alternative to surgery in a growing variety of settings.
Publication (Name of Journal)
Journal of the College of Physicians and Surgeons Pakistan
Recommended Citation
Ashraf, O.,
Ali, S. A.,
Tanveer-ul-Haq, .,
Sharif, H.
(2006). Endovascular stenting of a leaking thoracic aortic pseudoaneurysm. Journal of the College of Physicians and Surgeons Pakistan, 16(11), 732-733.