Evaluation of a point-of-care multiplex immunochromatographic assay for the diagnosis of typhoid: Results from a retrospective diagnostic accuracy study

Document Type

Article

Department

Pathology and Laboratory Medicine

Abstract

There is a clear medical need for an accurate diagnostic test for typhoid that can be performed at point of care. Two antigens (lipopolysaccharide [LPS] and hemolysin E [HlyE]) have recently been identified that can distinguish typhoid from other bacterial infections. Here, we present the results of a diagnostic accuracy study of the Dual Path Platform (DPP) Typhoid assay (Chembio) that detects IgA to both LPS and HlyE using blood culture as the reference standard. This was a retrospective, observational, laboratory study conducted at the Aga Khan University research laboratory, Pakistan, to evaluate the sensitivity and specificity of the DPP Typhoid assay, using archived frozen serum samples collected during a previous typhoid diagnostic accuracy study (NCT04801602). The sensitivity, specificity, and accuracy (area under the receptor operating characteristics curve [AUC]) were then assessed using the manufacturer's and Youden's optimal thresholds. In total, 385 samples were included in the analysis. Using the manufacturer's thresholds, the sensitivity, specificity, and AUC were 97.8% (95% confidence interval [CI] 94.6-99.2), 65.3% (95% CI 58.5-71.6), and 81.5% (95% CI 75.5-85.3), respectively. At Youden's optimal threshold, the overall sensitivity of the DPP Typhoid assay was 89.7% and the specificity was 82.2%. In latent class modeling compared with other nine rapid diagnostic tests evaluated from the same cohort sample, the DPP Typhoid assay demonstrated the highest balanced accuracy (89.2%). The DPP Typhoid assay demonstrated a high diagnostic accuracy for typhoid fever. However, further adjustment to new thresholds is recommended to enhance its performance capabilities.
Importance: Currently available diagnostic tests for typhoid have several limitations, including low sensitivity and specificity. Dual Path Platform Typhoid assay is a multiplex rapid test that detects IgA antibodies to lipopolysaccharide and hemolysin E antigen. It is considered to have high sensitivity and specificity, and its results were found to be highly correlated with ELISA results. However, very few studies have been conducted to evaluate this test and limited information about the accuracy of this test is present. Hence, this study evaluated the new typhoid test.

Comments

Volume, issue and pagination are not provided by the author/publisher.

Publication (Name of Journal)

Journal of Clinical Microbiology

DOI

10.1128/jcm.00428-24

Share

COinS