Document Type

Article

Department

Anaesthesia; Surgery

Abstract

Left Atrial pressure monitoring is a useful and accurate method to guide Left ventricle filling in the patients who undergo Arterial switch operation for transposition of great arteries. We have used a different technique in three TGA patients for LA pressure monitoring line placement. After cleaning and draping,right internal jugular vein (rt IJV) located through 22G venous cannula, guide wire was put in followed by sliding the 22Gx8cm vygon arterial catheter over the guide wire into the right atrium that was directed transatrially into LA by the operating surgeon during atrial septum repair. The catheter was secured by silk on the neck and dressed with transparent dressing and was kept for a period of 48-72hrs. LA pressure monitoring is helpful in anticipating LV dysfunction in ASO.

Publication (Name of Journal)

Journal of Pakistan Medical Association

Included in

Surgery Commons

Share

COinS